Features • Product Description • Thermal Performance
Available Sizes • Vertical Section • Horizontal Section • Mullion details
Photo Gallery • Installation Instructions
PERFORMANCE
CAN/CSA-A440-M90
Air Leakage fixed | Fixed | ( 0.023 (m 3/h)/m ) ( Fixed< 0.25 (m 3/h)/m |
Water Leakage | B7 | ( 700 Pa = 120 km/h ) approx = 14 lbs/ft^2 |
Wind Load C3 | C5 | (passes 5000 Pa blowout) approx 104 lbs/ft^2 |
CAN/CSA-A440.1-M91 Energy Rating up to +14 W/m^2K
These characteristics exceed NWDA’s requirements for Grade 60
FRAME & SASH
Fiberglass profiles are made from more than 60% glass fibres. The balance is polyester resin and performance additives. The glass fibres are made by spinning melted silica sand. The thermoset polyester resin is based on a petroleum derived alkide. The frame and sash are insulated with expanded polystyrene. Frame corners are assembled with foam filled glass reinforced nylon corner keys. . Standard frame depth is 3 ¼”. For door sidelites and transoms, as well as windows with mullions between large glass areas, use the optional 4 ½” frame.
BRICKMOULD
Extruded aluminums brickmoulds are available with and without integral nailing fins.
FINISH
All exposed portions of the fiberglass profiles are painted. Standard finish is Grafted Coatings’ K™-4. This water borne acrylic/urethane meets AAMA 613-96 and 615-96 (draft). All profiles are stocked in white. Custom colours are available. Also available is a real oak veneer interior.
JAMB EXTENSIONS
Wood jamb extensions are available in many depths and species, including pre-primed, veneer wrapped strawboard and ‘river bottom’ pine.
GLASS
The insulating glass conforms to CAN/CSGB-12.8-M90. Minimum glass thickness is 3mm or 1/8” (double strength). Both double glazing (22mm or 7/8” overall thickness) and triple glazing (37mm or 1 7/16” overall thickness) are available. All glazing is dual sealed and made with Edgetech’s SuperSpacer ™. Glass thickness is determined by the National Building Code of Canada.
High performance glazing options include; SOLERA ™ ,’self-cleaning’ glass, spectrally selective daylighting glass, tinted glass, reflective glass, Heat Mirror ™, pyrolitic (hard coat) low emissivity glass and sputtered (soft coat) low emissivity glass, as well as standard safety glass options.
GLAZING
The glass is held in place by a removable interior fiberglass glass stop. Double sided foam tape on the exterior and thermoplastic rubber on the interior assist in securing the glass. The glazing cavity is face drained to the exterior through injection moulded caps. The glazing cavity is also face vented to the exterior through two 1/16” vent holes.
MUNTINS
Muntin options include Georgian grilles between glass and two types of simulated divided lites in both double and triple glazing.
Our continuous improvement policy means that we may, without notice, change our product at any time.